The following parameters can be set in the 'ABULiner' parameter level of the LIS-SV.
|
Parameter |
Designation |
See |
|
5.10 |
Calling up the parameter level |
|
|
5.11 |
Activating the LIS-SV for the ABULiner |
|
|
5.11 |
Setting the gear ratio |
|
|
5.12 |
Activating double lifting speed |
|
|
5.14 |
Setting the run-on time of the auxiliary fan |
|
|
Danger during setting work! During setting work on the LIS-SV, monitoring of the wire rope hoist is switched off. This means the wire rope hoist cannot be monitored for excess load, among other things. This means the wire rope hoist cannot be monitored for excess load, among other things. This in turn means the load could fall and kill or injure people! Do not use the crane for normal work during setting work, and only lift loads very carefully for test purposes! |
All LIS-SV parameters which are important for the ABULiner are combined in a separate parameter level, which is shown as a submenu.
|
|
Move the load hook out of
the limit switch range (up or down).
During parameter setting, the load hook must not be within the limit switch range.
Open the menu of the
LIS-SV. See the documentation “Load indicator system LIS-SV”.
|
| |
|
Enter button |
Arrow buttons |
Select parameter 5.10.
Press ENTER.
● The 'ABULiner' parameter level is activated.
● Parameter 5.11 is displayed.
|
| |
|
Enter button |
Arrow buttons |
Select parameter 5.99.
Press ENTER.
● The previous parameter level is reactivated.
● Parameter 5.10 is displayed.
The LIS-SV is automatically activated for the ABULiner if a value is entered for the parameter 5.11.
In the ABULiner mode (a value is set for parameter 5.11):
─ The LIS-SV can monitor the total load for a maximum of two wire rope hoists.
─ Input F3 (normally used for measuring the load of wire rope hoist 3) now serves in monitoring the current rotational frequency of the hoist motor.
─ A value can be entered for parameter 3.0 (maximum load capacity of wire rope hoist 3). If a value is entered for this, parameter 5.11 cannot be set.
─ This interlocking thus excludes an incorrect setting.
─ The load-controlled switching point at output TxD of the LIS-SV cannot be used.
─ Parameter 4.5 (setting for load-controlled switching point) is not available.
In the normal mode (no value is set for parameter 5.11):
─ Operation of the ABULiner Lifting/Lowering unit is not possible.
─ The LIS-SV can monitor the total load for up to three wire rope hoists.
─ Input F3 serves in measuring the load of a third wire rope hoist.
─ A value can be entered for parameter 5.11 (gear ratio). If a value is entered for this, parameter 3.0 cannot be set.
─ This interlocking thus excludes an incorrect setting.
─ The load-controlled switching point at output TxD of the LIS-SV can be used.
─ Parameter 4.5 (setting for load-controlled switching point) can be used.
The LIS-SV uses the signal of the encoder and the gear ratio of the hoisting gear to calculate the hook travel distance, the maximum distance in the limit switch range and the current rotational frequency of the hoist motor. The gear ratio must be set on the machine.
|
| |
|
Cable speed |
|
Read off the type
designation at the type plate of the wire rope hoist.
Read off the cable
speed.
From this table, select
the gear ratio that matches the cable speed.
|
Cable speed | |||||
|
Hoist motor GM |
32 m/min at 50 Hz |
25 m/min at 50 Hz |
20 m/min at 50 Hz |
16 m/min at 50 Hz | |
|
800.4 |
50.01 |
63.49 |
77.77 |
98.16 | |
|
800.5 |
47.03 |
60.04 |
74.66 |
95.03 | |
|
1000.6 |
54.43 |
68.91 |
84.00 |
105.1 | |
|
1000.7 |
54.60 |
68.06 |
81.45 |
104.6 | |
|
2000.3 |
58.22 |
74.23 |
91.19 |
118.4 | |
|
3000.4 |
73.61 |
93.92 |
118.4 |
152.9 | |
|
5000.3 |
85.14 |
109.3 |
132.8 |
169.0 | |
|
5000.4 |
80.20 |
104.9 |
127.7 |
160.6 | |
|
6000.3 |
94.69 |
118.5 |
149.6 |
182.7 | |
|
7000.1 |
118.0 |
148.3 |
182.6 |
232.0 | |
Table: Gear ratios (numerical values) depending on hoist motor (lines) and cable speeds (columns) at 50 and 60 Hz.
|
| |
|
Enter button |
Arrow buttons |
Move the load hook out of
the limit switch range (up or down).
During parameter setting, the load hook must not be within the limit switch range.
Select parameter 5.11.
Press ENTER.
● The set value is displayed.
If the value is 0.00, the function is deactivated.
● Hold ENTER pressed.
● CODE is displayed.
Hold ENTER pressed.
|
| |
|
Enter button |
Arrow buttons |
Enter the code 1443.
Press ENTER briefly.
|
| |
|
Enter button |
Arrow buttons |
Set the value from the
table.
If the display ‘0.00’ cannot be changed, a value is set in parameter 3.0. In this case, set the value to zero first.
Press ENTER briefly.
"The Addams Family" (1991) là minh chứng cho thấy một tác phẩm điện ảnh hay sẽ không bao giờ bị lãng quên. Việc từ khóa "the addams family 1991 vietsub 2021" phổ biến trở lại là một tín hiệu vui, cho thấy khán giả trẻ ngày nay vẫn luôn trân trọng và tìm kiếm những giá trị nghệ thuật đích thực của quá khứ.
2021 was truly a year for rediscovering and celebrating the gothic charms of the 1991 classic. While the official 4K restoration gave the film a spectacular new look, the release of a thoughtful Vietnamese subtitle ensured its heart and humor were more accessible than ever. The "vietsub" played a crucial role in ensuring that "The Addams Family" remains creepy, kooky, and altogether connected across different languages and generations.
Bộ phim xây dựng một thế giới u ám, ma mị nhưng lại vô cùng cuốn hút. Từ ngôi biệt thự cổ kính đầy bẫy ngầm, những sinh vật kỳ quái (như bàn tay biết đi "Thing") cho đến gu thời trang Gothic quý phái của Morticia và Gomez. Tất cả tạo nên một bữa tiệc thị giác không thể trộn lẫn. Sự Đảo Ngược Giá Trị Hài Hước
The 1991 live-action adaptation of is a cult classic that successfully translated the macabre charm of Charles Addams' original cartoons into a visually striking, high-energy cinematic experience. Despite a turbulent production that saw the film change studios midway through, it became a massive commercial success and a defining entry in the franchise. The "Kooky" Premise the addams family 1991 vietsub 2021
: Available for streaming in Southeast Asian regions. Plot Overview
: Offers the 1991 film with official Vietnamese subtitles.
Điều gì khiến một bộ phim ra mắt từ năm 1991 vẫn giữ nguyên giá trị sau ba thập kỷ? Câu trả lời nằm ở tư duy nghệ thuật vượt thời gian và thông điệp nhân văn ẩn sau vẻ ngoài quái dị. Phong Cách Gothic Độc Đáo "The Addams Family" (1991) là minh chứng cho
Lloyd’s physical transformation and comedic timing brought a necessary heart to the spooky household. Why Search for "The Addams Family 1991 Vietsub 2021"?
The Addams Family 1991 không đơn thuần là một bộ phim giải trí, nó là một biểu tượng văn hóa. Việc từ khóa hot trở lại là minh chứng cho thấy giá trị của những tác phẩm nghệ thuật chân chính sẽ không bao giờ bị mai một theo thời gian. Nếu bạn đang tìm kiếm một bộ phim vừa hài hước, vừa kinh dị, lại mang thông điệp gia đình ấm áp, đây chắc chắn là lựa chọn không thể bỏ qua.
The 1991 cinematic adaptation of The Addams Family , directed by Barry Sonnenfeld, remains a definitive piece of gothic comedy. While the 2021 Vietnamese-subtitled (vietsub) re-releases brought the film back into the digital spotlight for a new generation, the core of the movie’s success lies in its subversion of the "perfect" American family. A Celebration of the Macabre While the official 4K restoration gave the film
Không thể nhắc đến The Addams Family 1991 mà không kể đến những khoảnh khắc đã đi vào huyền thoại:
Mặc dù vẻ ngoài và sở thích của nhà Addams có phần "bất bình thường" so với xã hội, nhưng họ lại có một gia đình hạnh phúc hơn bất kỳ ai. Họ không giả tạo, không phán xét và luôn bảo vệ nhau trước mọi sóng gió. Bộ phim gửi gắm thông điệp mạnh mẽ về việc chấp nhận sự khác biệt của bản thân và người khác. Thiết kế bối cảnh và thời trang đỉnh cao
The auxiliary fan of the hoist motor continues to run for several minutes after the lifting or lowering. This ensures that the hoist motor is adequately cooled even at slow lifting speeds. The run-on time can be adjusted.
|
| |
|
Enter button |
Arrow buttons |
Move the load hook out of
the limit switch range (up or down).
During parameter setting, the load hook must not be within the limit switch range.
Select parameter 5.14.
Press ENTER.
● The set value is displayed.
|
| |
|
Enter button |
|
Set the value to between 3
and 10 minutes using the arrow buttons.
Press ENTER.